Title:
|
Analyse meetresultaten PV-installatie te Zandvoort 2e semester 1994
|
|
Author(s):
|
|
|
Published by:
|
Publication date:
|
ECN
|
1995
|
|
ECN report number:
|
Document type:
|
ECN-C--95-004
|
ECN publication
|
|
Number of pages:
|
Full text:
|
38
|
Download PDF
|
Abstract:
The results of measurements, executed at the PV-installation on the roof of a zero-energy house in Zandvoort, Netherlands, are analyzed. The system
comprises 64 PV-panels and two grid-connected DC/AC inverters. The total
installed capacity is 3.3 kWp. The solar radiation on the reference cells was 511 kWh/m2 within the measuring period of the last 26 weeks in 1994. The energy yield of the inverters' output to the grid was 901 kWh. The efficiency of the inverter was as expected. The reliability of the panels, the cables and other components is good.
10 figs., 1 tab., 3 refs.
Back to List