Publications

Skip Navigation Links.
Recently Published
Expand per documenttypeper documenttype
Expand per Unitper Unit
Expand per Clusterper Cluster

Search for publications:


Limit search to the fields

ECN publication
Title:
Improved treatment of the strongly varying slope in fitting solar cell I-Vcurves
 
Author(s):
 
Published by: Publication date:
ECN 1996
 
ECN report number: Document type:
ECN-RX--96-022 Other
 
Number of pages: Full text:
6 Download PDF  

Abstract:
Straightforward least squares fitting of l-V curves leads to non optimalfits: residuals around and above the open-circuit voltage dominate the fit, leading to a bad fit at the maximum power point and lower voltage values. To deal with this problem, the authors have resorted to using weighting functions or to minimizing the area between data and fit instead of the least squares procedure. Both approaches lack a sound statistical basis. Voltage noise has a big influence on fitting due to the steep slope of an l-V curve for higher voltage values. For this reason the authors have used Orthogonal Distance Regression (ODR), which is a mathematical method for fitting measurements with errors in both voltage- and current measurements. It allows for computing both the l-V curve parameters and their uncertainties. 4 figs., 1 tab., 12 refs.


Back to List