Title:
|
Evaluatie meetresultaten 1 kWp a-Si PV-centrale te Petten
|
|
Author(s):
|
|
|
Published by:
|
Publication date:
|
ECN
|
1995
|
|
ECN report number:
|
Document type:
|
ECN-C--94-095
|
ECN publication
|
|
Number of pages:
|
Full text:
|
63
|
Download PDF
|
Abstract:
In the period June 1992 - May 1994 measurements were carried out on
twogrid-connected photovoltaic (PV) power systems of 1 kWp, one on the basis of amorphous silicon and one on the basis of polycrystalline silicon. The measured results are presented and discussed. The PV systems are situated in the dunes at the Netherlands Energy Research Foundation (ECN) in Petten, Netherlands. The aim of the title project was to gain field experience under typical Dutch climatic conditions. Results indicate a high inverter efficiency but a drop in the dc system efficiency from 4% to 2.2%, due to defective modules and, to a smaller extent, intrinsic module degradation.
After replacement of the defective modules the efficiency of the total system was restored to 3.8%. A subarray consisting of original modules showed an efficiency of 3.5% after one year of operation. Apart from the module related problems that have been solved, it is concluded that the system operated very reliable. The efficiency of the polycrystalline silicon PV system was maximal 10%. The annual averaged efficiency of the dc/ac conversion was more than 90%.
8 figs., 9 tabs., 7 refs.
Back to List