Title:
|
Analyse meetresultaten PV-woningen te Heerhugowaard: periode1994
|
|
Author(s):
|
|
|
Published by:
|
Publication date:
|
ECN
|
1995
|
|
ECN report number:
|
Document type:
|
ECN-C--95-116
|
ECN publication
|
|
Number of pages:
|
Full text:
|
70
|
Download PDF
|
Abstract:
Data from measurements, carried out in 1994, on 4 roof-integratedgrid-connected photovoltaic systems of 4 single-family dwellings in
Heerhugowaard, Netherlands, are presented. The yield factors vary from 0.60
to 0.75. The energetic conversion efficiency of the SMA inverters is circa
83% and the energetic conversion efficiency of the so-called Victron
inverters is circa 91%. Also, attention is paid to the different performances
of the three configurations of the installation: SMA inverters in cascade,
SMA inverters parallel, and Victron inverters in stand-alone operation. The
Maximum Power Point Trackers (MPPT) of the SMA inverters appear to be very
sensitive for varying radiations and super-sensitive for high ambient
temperatures of the inverter. Also, the DC-efficiency of the systems with
Victron inverters is not efficient within the radiation area of 50-300 W/m2.
1 figs., 7 tabs., 7 refs., appendices
Back to List