Publications

Skip Navigation Links.
Recently Published
Expand per documenttypeper documenttype
Expand per Unitper Unit
Expand per Clusterper Cluster

Search for publications:


Limit search to the fields

ECN publication
Title:
Measurement of wind turbine noise immission with a two-microphone technique
 
Author(s):
 
Published by: Publication date:
ECN 1996
 
ECN report number: Document type:
ECN-C--96-074 ECN publication
 
Number of pages: Full text:
32 Download PDF  

Abstract:
The measurement of wind turbine noise at an immission point at a largedistance from the turbine is very often hindered by the high contribution of the ambient noise and of the wind-induced noise in the microphone. The use of a 2-microphone technique for the measurements could reduce the measured contribution of the ambient noise and the wind-induced microphone noise without the suppression of the measured wind turbine noise. The merits of this technique were assessed experimentally, both in the time domain and in the frequency domain. It is concluded that the measured contribution of the ambient noise and wind-induced microphone noise is indeed reduced significantly. However, also the measured contribution of the wind turbine noise is reduced to a certain extent. For this reason the application of the technique for wind turbine immission measurements is not recommended. 11 figs., 3 tabs., 2 refs.


Back to List