Publications

Skip Navigation Links.

Search for publications:


Limit search to the fields

ECN publication
Title:
Kleinschalige houtverbranding: installatie en afname van twee houtkachels ten behoeve van ruimteverwarming
 
Author(s):
 
Published by: Publication date:
ECN 1998
 
ECN report number: Document type:
ECN-C--98-021 ECN publication
 
Number of pages: Full text:
26 Download PDF  

Abstract:
Two wood stoves were installed and purchased at the Netherlands EnergyResearch Foundation (ECN) in 1997: a manually to be filled 50 kW stove (Froeling FH-G TURBO 2000/50) and a fully automated 70 kW stove (Froeling Lambdamatic 60). The stoves are connected to the central heating system of one of the ECN buildings and to an external cooling system to test the stoves independent of the heat demand of the building. During the heating season the two wood burners are in operation instead of the two gas-fired heating appliances. The installation is equipped with instrumentation to measure and record the composition of the flue gas (O2, CO2, CO, CxHy, NOx, SO2). The 50 kW stove was put into operation in October 1997 and the 70 kW stove in March 1998. Flue gas composition, biomass input, output of ashes and flue gas temperatures were measured. Also mass balances and energy balances were set up for both wood burning appliances